Model NO.: YSX980A
Input Power: Single Phase 220VAC, 50/60Hz
Weight: 200kg
Generator Type: High Frequency Inverter
Radiographic Ratings: Large Focal Point 20-35kv/1-
Frequency: 40kHz
Power Rating: 1.2kw
Sid: 65cm
Mammography X-ray Equipment No.: Ysx980A/B
Trademark: YSENMED
Transport Package: Standard Export Wooden Case
Specification: 3.5kw/5.0kw
Origin: China
Model NO.: YSX980A
Input Power: Single Phase 220VAC, 50/60Hz
Weight: 200kg
Generator Type: High Frequency Inverter
Radiographic Ratings: Large Focal Point 20-35kv/1-
Frequency: 40kHz
Power Rating: 1.2kw
Sid: 65cm
Mammography X-ray Equipment No.: Ysx980A/B
Trademark: YSENMED
Transport Package: Standard Export Wooden Case
Specification: 3.5kw/5.0kw
Origin: China
Hospital  High Frequency  40khz   Mammography x-ray machine costModel:   YSX980A/B
X-ray GeneratorÂ
Generator Type | High Frequency Inverter 40kHz |
Input Power | Single phase 220VAC, 50/60Hz |
Radiographic Ratings | Large Focal Point 20-35KV/1-300mAs Small Focal Point 20-35KV/1-100mAs |
Power Rating | 1.2kW |
Type | High Frequency |
Technical parameters and configuration:
X-ray TubeÂ
Model: Fixed anode, China Hang Zhou XD7(X791)
Focal Spot Size: Dual Focus 0.5mm
Target Material: Molybdenum (Mo)
Port Material: Beryllium (Be)
Anode Heat Storage: 63KHU
Anode Cooling: Air cooling
Filtration: Mo(0.03mm),Al(0.5mm)
Â
Radiographic StandÂ
C-ARM: Vertical Movement:60cm (70~130cm) Motorized
Rotations Deg:±180° Motorized (Deg. Data Display)
SID: 65cm
Cassette Image ReceptorÂ
18×24cmÂ
Line VoltageÂ
220Vac@15A,Single phase
Weight:200kg
Bucky: (Optional)
Bucky Device:18×24cm Bucky drive mechanism
Grid Ratio:3.5:1 ,30 Line/cm
Comfortable Compression(Optional)
When some degree of pressure is required for radiography, it allows you to presser the appropriate pressure
(up to a maximum of 20kg)and is equipped with MICOM Control's Soft-touch system which is designed to minimize the discomfort of the examine with in the pressure range.
Tissue Compression: Manual and Motorized (Max 20kg)
Compression Force and Thickness Data Display
Micom Control's Compression
Automatic Release
Intelligent Automatic Exposure Control (AEC) (Optional)Â
With the Automatic Exposure Control system, it is possible to produce images with reliable intensity suitableÂ
for and film, screen, or method of radiography.Â
Furthermore, it greatly enhances the convenience of radiography by embedding the Full-AEC function which is capable of utilizing the Auto kV
Type: Solid-State Detector or PMT Detector
Microprocessor Control
AEC Mode: Full AEC(Auto kV)
Semi AEC (KV Select)
Manual (kV, mAs Select)
Density Adjustment: 10 density steps
Â
Please let us know your specfic request. We would like to recommend you the most suitable model based on your information. Â
 Hospital  High Frequency  40khz   Mammography x-ray machine cost
Model:Â Â Â YSX980A/B
X-ray GeneratorÂ
Generator Type | High Frequency Inverter 40kHz |
Input Power | Single phase 220VAC, 50/60Hz |
Radiographic Ratings | Large Focal Point 20-35KV/1-300mAs Small Focal Point 20-35KV/1-100mAs |
Power Rating | 1.2kW |
Type | High Frequency |
Technical parameters and configuration:
X-ray TubeÂ
Model: Fixed anode, China Hang Zhou XD7(X791)
Focal Spot Size: Dual Focus 0.5mm
Target Material: Molybdenum (Mo)
Port Material: Beryllium (Be)
Anode Heat Storage: 63KHU
Anode Cooling: Air cooling
Filtration: Mo(0.03mm),Al(0.5mm)
Â
Radiographic StandÂ
C-ARM: Vertical Movement:60cm (70~130cm) Motorized
Rotations Deg:±180° Motorized (Deg. Data Display)
SID: 65cm
Cassette Image ReceptorÂ
18×24cmÂ
Line VoltageÂ
220Vac@15A,Single phase
Weight:200kg
Bucky: (Optional)
Bucky Device:18×24cm Bucky drive mechanism
Grid Ratio:3.5:1 ,30 Line/cm
Comfortable Compression(Optional)
When some degree of pressure is required for radiography, it allows you to presser the appropriate pressure
(up to a maximum of 20kg)and is equipped with MICOM Control's Soft-touch system which is designed to minimize the discomfort of the examine with in the pressure range.
Tissue Compression: Manual and Motorized (Max 20kg)
Compression Force and Thickness Data Display
Micom Control's Compression
Automatic Release
Intelligent Automatic Exposure Control (AEC) (Optional)Â
With the Automatic Exposure Control system, it is possible to produce images with reliable intensity suitableÂ
for and film, screen, or method of radiography.Â
Furthermore, it greatly enhances the convenience of radiography by embedding the Full-AEC function which is capable of utilizing the Auto kV
Type: Solid-State Detector or PMT Detector
Microprocessor Control
AEC Mode: Full AEC(Auto kV)
Semi AEC (KV Select)
Manual (kV, mAs Select)
Density Adjustment: 10 density steps
Â
Please let us know your specfic request. We would like to recommend you the most suitable model based on your information. Â
Â
Garlic, perennial herbs, liliaceous allium.Subterranean bulb is divided into purple seed and white seed according to skin color.Pure white garlic spicy, pungent smell, edible or for seasoning, also medicine, by the public favorite food.Garlic is nutritious: 69.8 grams of water per 100 grams, 4.4 grams of protein, 0.2 grams of fat, 23.6 grams of carbohydrates, 5 milligrams of calcium, 44 milligrams of phosphorus, 0.4 milligrams of iron, and C3 milligrams of vitamin c.We provide the best quality for the customer, if you have any need, please tell us.
Pure White Garlic,Pure White Fresh Garlic,Natural Pure White Garlic,Quality Pure White Garlic
Jining Sunagro Trade Co., Ltd. , https://www.sunagro-food.com