Tianhui electronic universal testing machine operating procedures free download

Electronic universal testing machine operating procedures

First, the pre-test inspection work:

1. All wiring is connected correctly.

2. The equipment should be preheated for at least 15 minutes before testing to ensure the stability of the sensor components.

3. Adjust the beam limiter to ensure that the beam does not move beyond the range and cause damage to the fixture or device.

4. The parameter settings of the equipment are consistent with the required test requirements.

Second, start the experiment:

1. The above related inspections and preparations have been completed.

2. The sensor and deformation channel have been calibrated.

3. The limit of the moving beam has been set.

4. The sensors, fixtures and test equipment are all suitable for the test to be carried out.

5. The test plan has been set.

6. After the test is completed, please ask the tester to save and file the test results, and fill out the "Test Operation Record Form".

Third, stop the test:

1. Depending on the test, you can choose to stop the test via the host control panel or software settings.

2. Pressing the Stop Button on the control panel will stop the moving beam at its current position, which is the most basic way to stop the test.

3. Pressing the "Emergency Stop Switch" will stop the moving beam at the current position. When the test may endanger the operator's personal safety or may cause damage to the specimen or fixture, press the "Emergency Stop Switch" to rotate clockwise. The switch can restart the system. Note that this switch is used in an emergency. This switch is not used as a stop switch during normal test.

4. No matter whether the moving beam touches the upper limit or the lower limit block, the moving beam will stop moving. Before starting the test, pay attention to the position of the limit block to prevent the clamp from colliding.

4. If the test is not done, turn off the power and unplug the power cord.

Fifth, the test machine computer can not access the Internet, so as to avoid losing data due to poisoning.

6. Personnel not involved in the operation of the test machine are not allowed to operate the test machine to avoid damage to the test machine.

Seven, keep the testing machine clean every day.

Eight, every 3-6 months of regular maintenance, add butter to the two sides of the screw, the test machine idling up and down several times, keeping the screw up and down lubrication.

Manual Massage Collapsible Foot Spa Massager

The Manual Massage Foldable Foot Spa Massager is a portable compact device designed to give your feet a relaxing massage experience. Its foldable design makes it easy to store and transport, making it ideal for the frequent traveler.

Massagers typically have multiple massage rollers that apply pressure to different areas of the foot, providing a deep-tissue massage that can help relieve tension and improve circulation. Some models also feature heating and vibration to further enhance the massage experience.

To use the massager, you simply fill it with water and turn it on. The water will heat up and the massage rollers will go into action to provide a soothing massage that will help relax your feet.

Overall, the Manual Massage Foldable Foot Spa Massager is an excellent choice for anyone looking to relieve foot pain and tension in the comfort of their own home.

Manual Massage Collapsible Foot Spa Massager,Foot Bath Massager Machine,Electric Heated Foot Spa,Foot Bath Tub

Huaian Mimir Electric Appliance Co., LTD , https://www.footspamachine.com

Posted on